Q. A 3 phase I.M. running with slip 5%. Its rotor input is 20kW then its power output is ____ if frictional losses are 1kW.

  • (A) 19.75kw
  • (B) 1.8kw
  • (C) 18kw
  • (D) 21kw
πŸ’¬ Discuss
βœ… Correct Answer: (C) 18kw