Q. Which of the following is the most effective method for the detection of extremely deep-lying defects:
  • (A) Dry residual method using DC surge
  • (B) Wet continuous method using half wave rectified current
  • (C) Wet residual method
  • (D) Dry continuous method using half wave rectified current with prods
πŸ’¬ Discuss
βœ… Correct Answer: (D) Dry continuous method using half wave rectified current with prods