Q. When variations are noticed in the front surface reflection, the test piece should be inspected for possible near surface discontinuities by:

  • (A) Using a lower frequency transducer
  • (B) Using a higher pulse energy
  • (C) Inspecting from the opposite side
  • (D) Calibrating on a smaller diameter flat bottom hole
πŸ’¬ Discuss
βœ… Correct Answer: (C) Inspecting from the opposite side