Q. 1) Phase lag of the frequency response of a second order system to a sinusoidal forcing function

(A) Is 30°
(B) Is 90° at the most
(C) Approaches 180° asymptotically
(D) Is 120°
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 2) Which of the following is not classified as a thermo electric pyrometer?

(A) Resistance thermometer
(B) Thermocouple
(C) Radiation pyrometer
(D) Optical pyrometer (disappearing filament type)
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 3) The temperature of tempering oil baths maintained at 400°C during heat treatment of steel is measured by a/an __________ thermocouple. 

(A) Chromel-alumel
(B) Iron-constantan
(C) Platinum-platinum/rhodium
(D) None of these
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 4) __________ are analysed using a polarograph.

(A) Isotonic solutions
(B) Solids
(C) Liquids
(D) Gases
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 5) __________ temperature scale assigns 0° to the 'ice point' and 80° to the 'steam point'. 

(A) Celcius
(B) Rankine
(C) Reumur
(D) Farenhite
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 6) Operating range of a temperature measuring instrument is 800 to 1600°C. It could be a/an __________ pyrometer. 

(A) Radiation
(B) Optical
(C) Photoelectric
(D) None of these
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 7) Flow rate measurement of hostile acids and alkalis can be most suitably done by a/an

(A) Venturimeter
(B) Orificemeter
(C) Magnetic flow meter
(D) Hot wire anemometer
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 8) Response of a linear control system for a change in set point is called

(A) Frequency response
(B) Transient response
(C) Servo problem
(D) Regulator problem
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 9) Nickel percentage in invar which is an iron-nickel alloy, and is used as a thermocouple material is

(A) 12
(B) 36
(C) 54
(D) 68
View Answer Discuss Share

R

Ram Sharma • 178.09K Points
Coach

Q. 10) Which of the following measurements can be made by the measurement of emf?

(A) PH value
(B) Degree of hydrolysis
(C) Composition of complex ions
(D) All of the above