Q. In an induction motor, when the number of stator slots is equal to an integral number of rotor slots

  • (A) there may be a discontinuity in torque slip characteristics
  • (B) a high starting torque will be available
  • (C) the maximum torque will be high
  • (D) the machine may fail to start
πŸ’¬ Discuss
βœ… Correct Answer: (D) the machine may fail to start
Explanation: when the number of stator slots is an integral multiple of a number of rotor slots the machine fails to start and this phenomenon is called cogging.

Explanation by: Mr. Dubey
when the number of stator slots is an integral multiple of a number of rotor slots the machine fails to start and this phenomenon is called cogging.