Q. A developer aids penetrant bleed out because of:

  • (A) Adequate removal of the excess penetrant
  • (B) Providing a contrasting background for visible dye indications
  • (C) Capillary action
  • (D) Proper emulsifier action
πŸ’¬ Discuss
βœ… Correct Answer: (C) Capillary action

Q. In the solvent removable penetrant process, excess penetrant is removed with:

  • (A) A water spray
  • (B) A hydrophilic scrubber
  • (C) A solvent spray
  • (D) Clean, lint free towels slightly moistened with solvent
πŸ’¬ Discuss
βœ… Correct Answer: (D) Clean, lint free towels slightly moistened with solvent

Q. Water based wet developer is applied:

  • (A) Immediately before removal of excess penetrant
  • (B) Immediately after removal of excess penetrant
  • (C) After a drying period following removal of excess penetrant
  • (D) For maximum sensitivity results
πŸ’¬ Discuss
βœ… Correct Answer: (B) Immediately after removal of excess penetrant

Q. Non-aqueous wet developer is applied:

  • (A) Immediately before removal of excess penetrant
  • (B) Immediately after removal of excess penetrant
  • (C) After the excess penetrant is removed and part surface is dried
  • (D) For maximum sensitivity results
πŸ’¬ Discuss
βœ… Correct Answer: (C) After the excess penetrant is removed and part surface is dried

Q. Dry developer is applied:

  • (A) Immediately before removal of excess penetrant
  • (B) Immediately after removal of excess penetrant
  • (C) After drying of the part
  • (D) For maximum sensitivity results
πŸ’¬ Discuss
βœ… Correct Answer: (C) After drying of the part

Q. Typical ranges of emulsifier dwell times are:

  • (A) 5 to 10 minutes
  • (B) 30 seconds to 1 minute
  • (C) 1 to 3 minutes
  • (D) 5 to 10 minutes
πŸ’¬ Discuss
βœ… Correct Answer: (C) 1 to 3 minutes

Q. Actual emulsification times are determined by:

  • (A) Experiment, during technique qualification
  • (B) Manufacturer's recommendations
  • (C) Code requirements
  • (D) None of the above
πŸ’¬ Discuss
βœ… Correct Answer: (A) Experiment, during technique qualification

Q. The colour of fluorescent penetrant under the presence of a UV light is:

  • (A) Yellow-green
  • (B) Red
  • (C) Blue
  • (D) Green
πŸ’¬ Discuss
βœ… Correct Answer: (A) Yellow-green

Q. What action is necessary if the penetrant is inadvertently allowed to dry on the test piece?

  • (A) Repeat the test, beginning with the pre-cleaning operation
  • (B) Re-wet the penetrant, begin dwell time again and continue
  • (C) Clean the penetrant off the surface and develop normally
  • (D) Clean the penetrant off the surface, wait 5 minutes and develop normally
πŸ’¬ Discuss
βœ… Correct Answer: (A) Repeat the test, beginning with the pre-cleaning operation

Q. What maximum water rinse pressure is considered safe for removal of excess penetrant in the water washable penetrant process?

  • (A) As low a pressure as possible, 50 PSI maximum
  • (B) to 200 PSI
  • (C) PSI maximum
  • (D) to 500 PSI
πŸ’¬ Discuss
βœ… Correct Answer: (A) As low a pressure as possible, 50 PSI maximum

Jump to